METAWRKSCHANGELOG

SCANNY

Milestone 0.4

Milestone 0.4ALEXA CONTROLDATE26 SEP 2026CHANGES12MILESTONE

Full ALEXA 35 control with a safety model built in: arm, confirm, verify, undo. Plus base-station health and Finder-style multi-select.

SAFETY 02

  • Arm, confirm, verify, undo

    Arm before you write, confirmations tied to one camera, a test-spare mode, a verified-control list, a wire log and UNDO.

    ALEXA

  • Bounded writes

    Every number is range-checked, some values are never written, RESET ALL only works off air, and typed confirms name one camera.

    ALEXA

NEW 05

  • ALEXA camera page

    Seven tabs, a 12-cell info bar, function keys, an RCP strip and arrow-key riding.

    ALEXA

  • Base-station health

    NO LIGHT, genlock and a health dot per base station, with fleet columns.

    LPS

  • ALEXA web remote link

    Open the camera's own remote on the network, through the same write safety.

    ALEXA

  • Fleet CHECK and COPY

    Compare cameras on the Wall; COPY settings to many cameras with an undo file saved first.

    ALEXA

  • Multi-select like Finder

    Click, Shift and Command select across every brand; COPY targets that selection.

IMPROVED 04

  • Stills step aside for control

    STILLS PAUSED, GRAB 1 and WAITING BEHIND STILL keep pictures out of the way of live changes. REC and STOP still go out at once; other replies can wait behind a still in progress.

    ALEXA

  • CAMERA FULL respected

    A camera that is full isn't knocked on again by itself; one connection per camera.

    ALEXA

  • Keyboard and fit

    Wall up/down follows the tile layout, CMD+SHIFT+L everywhere, labels fit at 940 × 600.

  • Tested against a full camera simulator

    ALEXA changes are tested on a simulator before release.

    ALEXA

FIXED 01

  • No silent retries

    A refused password never retries by itself; web changes are checked by their effect on the camera.

    ALEXA