SCANNY
1.1.0 beta 30
1.1.0 beta 30ChainDATE14 OCT 2026CHANGES07BETA
CHECK: one press checks the whole signal path, shows where each camera's picture stops, and exports a one-page proof per camera. ColorBox verdicts now rest on each box's own settings.
NEW 02
CHECK tab: the signal chain per camera
A new tab after MAP follows each camera through nine steps: camera SDI out, fiber, base station in, CCU out, ColorBox in and out, router in and out, and the destination. Each step is proven, broken, not read, or known only by label. Where the picture stops is marked between the last step proven good and the first proven bad; a step Scanny could not read is never blamed, and a box matched only by guess never raises an alarm.
CHECK EVERYTHING and a proof page per camera
One press (or Cmd+Return) checks the ColorBoxes, the router, the base stations and Livegrade together. EXPORT writes the whole truck or a single camera's chain: an index, a one-page proof per camera with the box pictures and waveform, the chain data, and the list of every request Scanny sent.
IMPROVED 04
Blame only what is at fault
Every view, report and export uses one rule: amber only for a problem at that device (a box's black output or a box setting such as Frame Store or bypass), grey for problems upstream or matches that are only a guess. A fleet line reads like 20 BOXES · 9 PASSING · 10 UPSTREAM · 0 AT BOX.
Router read in more detail, still read only
Scanny now reads the router's output locks, model and which ports are fitted, on the connection it already had. It still sends the router nothing.
ColorBox verdicts rest on the box's own settings
Whether a box is processing now comes from its active mode, the same way AJA's own web page reads it: LUT stages, Colorfront, Orion, BBC or NBC. PASSING · NO LUT needs the settings to confirm it; otherwise Scanny grabs the output once more, and if it still matches the input the verdict is OUTPUT NOT CONFIRMED, with no claim either way.
HELPER: ColorBox connectors
The ColorBox notes now describe the rear panel as SDI In, SDI Loop Out (the raw input, no LUT) and SDI Out (processed), plus HDMI: a feed taken from LOOP shows ungraded log, never the LUT.
FIXED 01
Livegrade devices from another job
A Livegrade device or router saved on a network this Mac is not on now reads SET UP · NOT ON THIS NETWORK in grey instead of LOST or ROUTER FAILED. A device that worked this session, or sits on any network the Mac has, still shows its real fault.